High Quality Metal Housing Piezo Ultrasonic Scaler, Metal Housing Piezo Dental Ultrasonic Scaler, Best Metal Housing Piezo Ultrasonic Scaler Suppliers in China

Home > Products > Air Source Treatment Regulator > Dental Piezo Ultrasonic Scaler

Dental Piezo Ultrasonic Scaler

Dental Piezo Ultrasonic Scaler

    Packaging: By paper box
    Productivity: 200 units / month
    Brand: ELiTEDENT
    Transportation: Ocean,Air,Express
    Place of Origin: Taiwan
    Supply Ability: 200 units / month
    HS Code: 9018
    Port: Port of Keelung

Basic Info

Model No.: PS-1

Product Description

Safety Precautions

Prior to installation and start-up of the ultrasonic scaler, carefully read the instructions provided herein!

Precautions for All Systems

1. Do not place the Ultrasonic Scaler on or next to a radiator or other heat source. Excessive heat may damage the Ultrasonic Scaler’s electronics. Place the Ultrasonic Scaler where air is free to circulate on all sides and beneath it. Do not cover vents on rear panel.

2. Always set the system's power adjustment to the lowest power setting for the application of a new or special Tips.

3. Always flush your Ultrasonic Scaler system for at least 30 seconds with highest flow after treatment.

4. Do not operate the system in “Turbo” mode continuously for more than 20 minutes! Try to take a 10 minute break before re-use the system.

5. Equipment and dental water supply system maintenance are strongly recommended.

6. Close the water shut-off valve in the dental water supply system every night before leaving the office.

7. The use of an in-line water filter is recommended.

8. Used for the intended purpose only. The Ultrasonic Scaler must be used by other than qualified and trained personnel, in medical facilities.

9. Grounding reliability can only be achieved when the equipment is connected to an equivalent receptacle marked Hospital Only or Hospital Grade.

Precautions for Ultrasonic Prophylaxis Procedures

1. Before first use, clean, disinfect and sterilize new or repaired handpieces and Tips you wish to use with the Ultrasonic Scaler.

2. Always examine the unit and ultrasonic tips before commencing treatment. A damaged Ultrasonic Scaler or damaged tip must not be used.

3. Ultrasonic tips that have been bent, damaged, or reshaped are susceptible to in-use breakage and should be discarded and replaced immediately.

4. Retract the lips, cheeks and tongue to prevent contact with the ultrasonic tip whenever it is placed in the patient's mouth.

Introduction

Rolence Enterprise Inc. is an ISO 9001, ISO 13485 certified manufacturer of Ultrasonic Scalers. All the products are FDA registered and compliant with EN standard (CE Marking).

Conformance to Standards:

ELiTEDENT® PS-1/PS-1(LED) Ultrasonic Scaler conforms to IEC60601-1-2:2001 and IEC60601-1-1:2000.

The device is CE marked corresponding to European Medical Device Directive (93/42/EEC)

Application

The Ultrasonic Scaler is designed for use in dentistry for the following applications:

- General Scaling (G)

Removal of supragingival calculus

Removal of stains

- Endo (E)

Preparation, cleaning and irrigation of root canals

Retrograde preparation of root canals

- Perio (P)

Scaling and root planning

Periodontal treatments

Installation Instructions

General Information

If the installation of your ELiTEDENT® Ultrasonic Scaler is performed by someone other than trained Rolence distributor personnel, care should be taken to observe the following requirements and recommendations.

Water Line Requirements

1. The System's water supply line is factory installed. Do not disconnect from the Ultrasonic Scaler.

2. Incoming water supply line pressure to the Ultrasonic Scaler must be 20 psi (138 kPa minimum) to 60 psi (414 kPa maximum). If your dental water system's supply line pressure is above 60 psi, install a water pressure regulator on the water supply line to your Ultrasonic Scaler.

3. A manual shut-off valve on the dental water system supply line should be used so that the water can be completely shut-off when the office is unoccupied.

4. A filter in the dental water system supply line is recommended so that any particles in the water supply will be trapped before reaching the Ultrasonic Scaler.

5. After the above installations are completed on the dental water supply system, the dental office water line should be thoroughly flushed prior to connection to the System.

6. After flushing system verify there are no leaks.


Rolence Enterprise Inc.

  • 1
  • 2
  • 3
  • 4
 

Rolence Enterprise Inc. headquartered in Taiwan, develops, manufacturing & innovation on small equipment of Ultrasonic Scaler, Portable X-Ray, Dental Digital Sensor and LED Curing Light...etc. For over 40 years, we are an international supplier of dental equipment for various companies .


Multi-innovative developments & processes, proven know-how and high-quality have given us a leading position to our customer. and keep up with the innovative and creative design concepts into our products chain by incorporating the dentists` and other technology industry needs.


Besides, with further office locations will be in Germany, we will keep expending our office establish in different country afterward, and supporting our customer latest information, product training, and marking media to increase your business, that`s why we are approaching you to present ourselves & the products to reach a good cooperation in the future.

Company Info

  • Company Name: Rolence Enterprise Inc.
  • Representative: Sterling Cheng
  • Product/Service: Portable X-Ray , Curing Light , Ultrasonic Scaler , Curing Box , Dental Digital Sensor , UV Spot Curing
  • Capital (Million US $): TWD$65,400,000
  • Year Established: 1981
  • Total Annual Sales Volume (Million US $): US$2.5 Million - US$5 Million
  • Export Percentage: 81% - 90%
  • Total Annual Purchase Volume (Million US $): US$1 Million - US$2.5 Million
  • No. of Production Lines: 3
  • No. of R&D Staff: 5 -10 People
  • No. of QC Staff: Fewer than 5 People
  • OEM Services Provided: yes
  • Factory Size (Sq.meters): Below 1,000 square meters
  • Factory Location: No. 18-3 , Lane 231, Pu Chung Rd., Chungli Dist., Taoyuan City, Taiwan R.O.C. 32083
  • Contact Person: Mr. Peter Chiu
  • Tel: +886-3-4631999
Email to this supplier
  • *Subject:
  • To:

  • *Messages:
    Your message must be between 20-8000 characters